• ELECTRONIC SINGLE FIBER STRENGTH TESTER- mould KS11 System 1
  • ELECTRONIC SINGLE FIBER STRENGTH TESTER- mould KS11 System 2
ELECTRONIC SINGLE FIBER STRENGTH TESTER- mould KS11

ELECTRONIC SINGLE FIBER STRENGTH TESTER- mould KS11

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications


1.Digital Reeling Twist Tester
2.To determine single or plied yarns twist by conventional or untwist/re-twistmethods



Application:  


Digital Reeling Twist Tester is designedto determine single or plied yarns twist by conventional or untwist/re-twistmethods.


Related Standards:    

Digital yarn twist tester

GB/T2543.1/2, 14345

FZ/T 10001

ISO 2061

ASTM D1422/1423

   Note: this tester can conform to but not limit to allthe standards above, for more standards conformance, please contact us.


Features:


1       Controlled by microcomputer,large-screen LCD displayer (made in CHINESE TAIWAN), support both Chinese andEnglish menus by switch, man-machine interactive dialogue operation;

2        With data storage function whenpower off, query up to 300 groups data, and print out test report in English orChinese optionally;

3         zero position is detectedby optocouple sensor to avoid zero shift caused by Hall sensor;

4         Right sample grip isderived high-performance direct-drive stepper motor, rotational speed can bearbitrary preset to avoid the problems of brush wear and spark interface whichis caused by DC motor completely;

5         Add the pre-tension athorizontal direction.


Key Specification:


1         Testmethods     1. Direct count;    

                                        2. Once twist/retwist method

                                       3. Twice twist/retwist method;    

                                        4. Triple twist/retwist method

2        Smplelength                     25,50,100,250,500(mm (selectable)

3         Range of tested yarn          1~499.9tex

4         Range oftest                    1~9999.9 twist

5         Rotationalspeed                 300~1200r/min(adjustable)

6         Metallic scaleaccuracy      1mm

7        Power supply                    AC220V  50Hz  20W

8        Instrumentsize                  1070 * 240 * 200mm

9        Instrumentweight               30kg














Q:What are the regulations for the air volume of the exhaust fan?
Bear two or more smoke partition smoke, should be the largest smoke partition area per square meter of not less than 120m3 / h basis.
Q:Axial fan installed directly on the wall exhaust, how to determine its wind pressure?
If you just want to know about the wind pressure, the current time can be measured.
Q:How is the suction of the centrifugal fan measured?
Centrifugal fans are mechanical machines that rely on the input of mechanical energy to increase the gas pressure and send the gas, which is a driven fluid machine. Centrifugal fans are widely used in factories, mines, tunnels, cooling towers, vehicles, ships and buildings for ventilation, dust and cooling;
Q:What is the principle of explosion-proof fan?
Applicable and transport flammable and explosive non-corrosive gases, the ambient temperature shall not exceed 60 ℃, widely used in general factories, warehouses, offices, residential ventilation or strong heating
Q:What is the role of the fan?
Gas compression and gas transport machinery is the conversion of mechanical energy into gas pressure energy and kinetic energy, and the gas transported out of the machinery.
Q:What is the difference between an axial fan and an axial fan?
The Axial fans are often used in situations where the flow rate is high and the pressure is low. The axial fan is fixed and moves the air. Axial fans are mainly composed of fan impellers and housings. The structure is simple but the data is very high.
Q:How to change the fan flow ah?
Bypass adjustment, suitable for Roots blower (volumetric fan);
Q:What is the reason for the vibration of the fan?
Fan of the impeller of the dynamic and static balance failed, with the fan after a certain period of time after the impeller uneven wear line caused by poor balance,
Q:380V axial fan has five lines how to take?
If not, there are two groups of the same, there is a group of different, but also a capacitor, then the axial fan should be a 220V power supply. If you want to change the direction of the fan, you must connect the power cord in the power cord to the other end of the capacitor.
Q:What is the difference between a blower and a blower?
The It can be seen that the wind pressure of the blower is great. Generally used in metallurgy, mining.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords