Model NO.:ZZ1166

 

Type:Rescue

Certification:ISO9000, CCC

 

Volume:3001-5000L

Emission Standard:Euro 3

 

Transmission Type:Manual

Engine Type:4 Stroke

 

Payload:18750

Fuel:Diesel

 

Drive Wheel:4×2

Horsepower:251-350hp

 

Condition:New

Fire Truck:Fire Fighting Truck

 

Power:Diesel

Truck Type:Fire Truck

 

Tire Design:Radial

Seats:≤5

 

Tire Certification:ISO

Tire Type:Solid Tire

 

Export Markets:Global

Additional Info.

Trademark:Veldlion

 

Packing:Nude Package or Roro Ship

Standard:Nude Package or Roro Ship

 

Origin:Hubei

HS Code:87053090

 

Production Capacity:3000PCS Per Month

Product Description

1. Technical parameters of the fuel tanker trucks .
(1) Foam fire fighting trucks

(2) Gross weight: 18750kg
(3) Water tanker volume: 3000 litres
(4) Foam tanker volume: 1000 litres
(5) Fire pump: CB10/40
(6) Fire monitor: PP40

chassis Model/ manufacturerZZ1166
CabDouble cabin (four doors)
overall dimensionL*W*Hmm8530*2500*3500
total mass(KG)Kg 18,750
Rated payloadKg 8,000
Kerb weight 
Kg 10,300
Approach/ departure angel 
"18/13
Front /rear suspension 
mm1560/2177
Fuel type dieselFuel consumption 32 L/100km
Ground clearance   mm248
Max speed Km/h90
EngineModel/ rated powerHpWd615.62 / 266 HP
Emission standard
Euro II or above
Rated speed r/nin2200
Max. torque
1100(N.m) / 1100~ 1600(rpm)
DisplacementML9726
Driving type 4*2Wheel base 4600mm
Front tread1958mmRear tread 1830mm
Front axle6500kgRear axle16000kg
Number of leaf spring of suspension9/9+6Type & size of tyre11.00-20
Electrical systemBattery capacity (A .h)2*12V 135Ah
Alternator capacity (A)28V 55A 1540W
Starter motor power (Kw)24V 7.5kw
Technical parameter of fire fighting body
Liquid tankerVolume: total 4000L (among, water: 3000L; foam: 1000L) 
Material:high quality carbon steel plate, anti-rust treatment inside.
Structure: welding, there is baffle plate inner
Equipment: 2 manholes, with speediness lock and turn on equipment, 2overflow mechanisms
Material of the tanker : stainless steel 304 
Fire fighting pump and pipeline systemModel of fire fighting pump: CB10/40
Pressure: 1.0Mpa
Flux: 40L/s
Suction depth:≥7m
Suction time: ≤35s
Installing type: central or rear
Pipeline system:
Suction pipeline: there is 125mm water inlet, can sop natural water source and sop the water from liquid tanker
Water outlet pipeline: there is one middle pressure water outlet on every side, and gun pipeling with dia.≥80mm on the top of tanker
Discharge remaining water system: to protect pump and all ball valves

Fire Fighting Truck   4*2 Double Cabin (Volume: 4000L) (ZZ1166)

Fire Fighting Truck   4*2 Double Cabin (Volume: 4000L) (ZZ1166)


Q:What is the area requirement of fire climbing area for multi-storey buildings?
6.0.2 has a closed courtyard or patio buildings, while the short side length is greater than 24.0m, the fire lane should be set to the inner courtyard or patio.6.0.3 has a closed courtyard or patio buildings along the street, should be pedestrian streets and communicated inner courtyard (use staircase), the distance should be less than 80.0m.6.0.4 in the fire lane across both sides of buildings or buildings into the courtyard, should not affect the security settings of the evacuation or fire truck traffic facilities.6.0.5 more than 3000 seat stadiums, more than 2000 seat halls, and more than 3000m2 of the exhibition hall and other public buildings, should be provided with ring fire lane.
Q:The fire truck generally how to paint?
Most of the fire engines in the country are red. Because it's the most eye-catching, you can see it from far away. However, according to the New York transportation department survey, red fire engines every 100 thousand trips, accident 32 times. And if the fire car painted more vivid yellow, each sent 100 thousand trips, the only 14.5 times, fell by more than half. Because the light color will make the outline of the car bigger, there is closer to their feeling, traffic safety advantages. So they decided to paint the fire engine yellow. But the fire department is strongly opposed to doing so, because the yellow people emotional stability, will reduce the efficiency of fire fighting, and red can inspire morale, exciting.
Q:How much is the height, width and turning radius of the fire lane
(4) the fire lane pipe and drain should be able to withstand the pressure of large fire truck.(5) the fire lane through the building of the door, the height and width of not less than 4 meters; gate stack between width of not less than 3.5 metres.(6) there should be an annular fire lane around the high-rise building. When there is difficulty in setting the ring fire lane, fire lane can be built along the two long sides of the building.
Q:Fire engine high-rise fire what are the frustration?
Fire engines generally have the following categories: water tankers, car, climbing ladders, high jet car, compressed air foam vehicles, rescue vehicles, car lighting etc..Tank car and various tonnage is 5 tons to 25 tons, a car 30 tons; take a car is to make a platform lift, the firemen sent up or to the above people saved; ladders than take a car more than a sliding bucket, bucket elevator can slide like. On transport; high jet car it is to fire guns held high, closer to the fire place.
Q:Can the fire engine go retrograde? What car can go retrograde?
In the implementation of the task of military vehicles, police cars, ambulances, fire trucks, engineering rescue vehicles and special vehicles to hold permits in the circumstances to ensure safety without traffic signs and markings limited, the red light will be retrograde
Q:What's the fire passage (size)?
Article 6.0.3 of the buildings should be set for the passage of streets and the inner court (by staircase), the distance should be more than 80m.Article 6.0.4 factories and warehouses shall be provided with fire lanes. A a, B and C plant covers an area of more than 3000m2 or a B C warehouse covers an area of more than 1500m2, should set the fire ring road, if there are difficulties, along the two long side set the fire lane or the settings for the passage of a fire truck and a width of not less than 6m flat space the.
Q:The fire vehicle fire when the fire should be charged?
Forty-ninth articleNo fees may be charged for fire fighting or emergency rescue by public security fire brigade or full-time fire brigade.The units, full-time fire brigades and volunteer fire brigades shall take part in the fuel, fire extinguishing agent, equipment and equipment that have been consumed by the units outside the fire, and shall be compensated by the people's government at the place where the fire occurred.
Q:Fire lane width should be no less than meters
4 for fire engines to take in natural water, fire pool should be equipped with fire lane.5 width of fire lane should not be less than 4.00m. Fire lane from high-rise building exterior wall should be greater than 5.00m, fire lane above 4.00m within the scope of the obstacles should not be.6 end fire lane should have back lane or return field, enter the field should not be less than 15mx15m. The return field of large fire engines should not be less than 18mx18m. The fire lane pipeline and Angou, should be able to withstand the pressure of fire fighting vehicles.7 through the fire lane of the high-rise building, its width and height clearance shall not be less than 4.00m.8, between fire lane and high-rise building, should not set up hinder climbing fire truck operation of trees, overhead pipelines.
Q:How can the fire engine go out when the gasoline is on fire?
Fire engines generally have the following categories: water tankers, car, climbing ladders, high jet car, compressed air foam vehicles, rescue vehicles, car lighting etc..Tank car and various tonnage is 5 tons to 25 tons, a car 30 tons; take a car is to make a platform lift, the firemen sent up or to the above people saved; ladders than take a car more than a sliding bucket, bucket elevator can slide like. On transport; high jet car it is to fire guns held high, closer to the fire place.
Q:What is the width of the construction fire lane?
A closed courtyard or patio high-rise buildings along the street, should be pedestrian streets and communicated inner courtyard (use staircase), the distance of not more than 80m.4.3.2 high-rise building courtyard or patio, while the short side length of more than 24m, should be equipped with fire lane into the inner court or patio.4.3.3 fire water should be provided for natural water sources and fire pools for fire engines

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords