• klikkon brass quick locking pipe clamp System 1
klikkon brass quick locking pipe clamp

klikkon brass quick locking pipe clamp

Ref Price:
$0.03 / pc get latest price
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days
Q:How can the clamp meter measure alternating current?
The general type for measuring current clamp meter, you open the jaw vise current wires can be, if you want to measure the AC voltage, can use the pen, with a multimeter used almost
Q:A selection table clamp type table
1, before use, should read the instruction manual carefully, make clear whether it is communication or AC and DC dual-use.2, the measured voltage clamp meter shall not exceed the values marked on the ground, otherwise easy to cause the accident, or cause the risk of electric shock.3, you can only measure the current one conductor, the measured wire clamp should be placed in the center of the window, the window with all phase conductors can not measure.
Q:A multimeter can measure AC current?
There are now many can directly use the clamp ring clamp meter to measure DC current, such as Fluke 317, type 319, China also has a lot of, major brands such as youlide, victory and so on have DC clamp meter, can use the "DC Clamp multimeter
Q:What do you mean by measuring current 2/20 and 200/600 stalls by clamp type?
Measure the range of gears, corresponding to AC, 2 to 20 amperes, 200 to 600 Amperes
Q:How to measure the static grounding resistance
The grounding resistance tester model is ZC29B. There are three lines: 20 meters of ground pile and 40 meter stake respectively
Q:How to measure the motor current with a multimeter?
Measurement of alternating current. The measuring method is the same as that of 1, but the gear should be switched to the AC gear. After the current measurement is completed, the red pen should be inserted back into the "V" hole.If the measuring range is enough, measure according to the above method. Does not recommend the use of multimeter with clamp current meter to measure the motor current recommendations. Safe and convenient.
Q:How do you measure the current of the equipment with a multimeter?
Connect the multimeter on the wire of the appliance. To do this, the first step is to switch off the appliance. The second step is to unplug the plug and connect the meter. The third step is to plug in the plug and close the switch. At this point, the meter reads for both.
Q:If there is no measurement capacitor on the table, then how to measure the quality of the capacitor?
If there is no current file, then for large capacitance measurement changes can be measured by the charging current of the way, also need to clamp meter has high resolution. For small capacitance, the charging current is not enough to push the clamp type table, it cannot measure!
Q:What are the commonly used tools for electrician maintenance?
Kit; high voltage electroscope, low voltage test pencil; nose pliers, diagonal pliers, pliers, stripping pliers, small crimping pliers; 6 inch, 8 inch, 12 inch wrench, six angle wrench, a 8-19 wrench set, 8-19 wrench set, 32 sets of a screw sleeve; a large, medium and small trumpet cross screwdriver, screwdriver set a special instrument (now a lot of terminals to be used);
Q:How to find out the broken capacitor in the three-phase capacitor of the reactive compensation cabinet with the clamp table?
Check the current size, each capacitor three times the same

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords